| HP ProCurve Switch 3500yl-24G-PWR Intelligent Edge (J8692A) | HP ProCurve Switch 3500yl-48G-PWR Intelligent Edge (J8693A) | HP ProCurve 3500-24 Switch (J9470A) |
| Ports |
|
1 open module slot
20 auto-sensing 10/100/1000 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T)
Media Type: Auto-MDIX
Duplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full only
1 RS-232C DB-9 console port
4 dual-personality ports
each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type 100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) with PoE or an open mini-GBIC slot (for use with mini-GBIC transceivers)
Supports a maximum of 4 10-GbE ports
|
1 open module slot
44 auto-sensing 10/100/1000 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T)
Media Type: Auto-MDIX
Duplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full only
1 RS-232C DB-9 console port
4 dual-personality ports
each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type 100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) with PoE or an open mini-GBIC slot (for use with mini-GBIC transceivers)
Supports a maximum of 4 10-GbE ports
|
20 RJ-45 auto-sensing 10/100 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX)
Media Type: Auto-MDIX
Duplex: half or full
4 dual-personality ports
Each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type 100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) or an open mini-GBIC slot (for use with mini-GBIC transceivers)
1 RS-232C DB-9 console port
|
| Physical characteristics |
| Dimensions |
15.43(d) x 17.44(w) x 1.73(h) in. (39.2 x 44.3 x 4.4 cm) (1U height) |
16.93(d) x 17.44(w) x 1.73(h) in. (43.0 x 44.3 x 4.4 cm) (1U height) |
15.43(d) x 17.44(w) x 1.73(h) in. (39.2 x 44.3 x 4.4 cm) (1U height) |
| Weight |
14.11 lb. (6.4 kg) |
16.09 lb. (7.3 kg) |
11.9 lb. (5.4 kg) |
| Memory and processor |
| 10G Module |
ARM9 @ 200 MHz; packet buffer size: 36 Mb QDR SDRAM |
ARM9 @ 200 MHz; packet buffer size: 36 Mb QDR SDRAM |
|
| Management Module |
Stackable memory and processor: Freescale PowerPC 8540 @ 666 MHz, 4 MB flash, 128 MB compact flash, 256 MB DDR SDRAM |
Stackable memory and processor: Freescale PowerPC 8540 @ 666 MHz, 4 MB flash Mb, 128 MB compact flash, 256 MB DDR SDRAM |
Stackable memory and processor: Freescale PowerPC 8540 @ 666 MHz, 4 MB flash, 128 MB compact flash, 256 MB DDR SDRAM |
| Mounting |
|
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
|
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
|
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
|
| Performance |
| 100 Mb Latency |
|
|
< 3.4 µs (LIFO 64-byte packets) |
| 1000 Mb Latency |
< 3.4 µs (FIFO 64-byte packets) |
< 3.4 µs (FIFO 64-byte packets) |
< 2.9 µs (LIFO 64-byte packets) |
| 10 Gbps Latency |
< 2.1 µs (FIFO 64-byte packets) |
< 2.1 µs (FIFO 64-byte packets) |
|
| Throughput |
up to 75.7 million pps |
up to 111.5 million pps |
up to 8.9 million pps (64-byte packets) |
| Routing/Switching capacity |
101.8 Gbps |
149.8 Gbps |
12 Gbps |
| Switch fabric speed |
105.6 Gbps |
153.6 Gbps |
|
| Routing table size |
10,000 entries |
10,000 entries |
10,000 entries |
| MAC address table size |
64,000 entries |
64,000 entries |
64,000 entries |
| Environment |
| Operating temperature |
32ºF to 131ºF (0ºC to 55ºC); 32°F to 104°F (40°C) when used with any X2 10-GbE |
32ºF to 131ºF (0ºC to 55ºC); 32°F to 104°F (40°C) when used with any X2 10-GbE |
32ºF to 131ºF (0ºC to 55ºC) |
| Operating relative humidity |
15% to 95% @ 104ºF (40ºC), non-condensing |
15% to 95% @ 104ºF (40ºC), non-condensing |
15% to 95% @ 104ºF (40ºC), non-condensing |
| Non-operating/Storage temperature |
-40ºF to 158ºF (-40ºC to 70ºC) |
-40ºF to 158ºF (-40ºC to 70ºC) |
-40ºF to 158ºF (-40ºC to 70ºC) |
| Non-operating/Storage relative humidity |
15% to 90% @ 149ºF (65ºC), non-condensing |
15% to 95% @ 149ºF (65ºC), non-condensing |
15% to 90% @ 149ºF (65ºC), non-condensing |
| Altitude |
up to 15,000 ft. (4.6 km) |
up to 15,000 ft. (4.6 km) |
up to 15,000 ft. (4.6 km) |
| Acoustic |
Power: 55.1 dB, Pressure: 44.8 dB ISO 7779, ISO 9296 |
Power: 55.6 dB, Pressure: 45.3 dB ISO 7779, ISO 9296 |
Power: 53.1 dB, Pressure: 42.6 dB ISO 7779, ISO 9296 |
| Electrical characteristics |
|
|
Achieved Miercom Certified Green Award |
|
| Description |
The switch automatically adjusts to any voltage between 100-127 and 200-240 volts and either 50 or 60 Hz |
The switch automatically adjusts to any voltage between 100-127 and 200-240 volts with either 50 or 60 Hz |
The switch automatically adjusts to any voltage between 100-127 and 200-240 volts and either 50 or 60 Hz |
| Maximum heat dissipation |
865 BTU/hr (912.9 kJ/hr) |
1144 BTU/hr (1206.9 kJ/hr) |
268 BTU/hr (282.8 kJ/hr) |
| Voltage |
100-127 / 200-240 VAC |
100-127 / 200-240 VAC |
100-127 / 200-240 VAC |
| Current |
10.0 / 5.0 A |
10.0 / 5.0 A |
1.1 / 0.6 A |
| Idle power |
98 W |
142 W |
68.2 W |
| Maximum power rating |
623 W |
705 W |
78.7 W |
| PoE power |
398 W |
398 W |
|
| Frequency |
50 / 60 Hz |
50 / 60 Hz |
50 / 60 Hz |
| Notes |
Idle power is the actual power consumption of the device with no ports connected. Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated. PoE Power is the power supplied by the internal power supply, it is dependent on the type and quantity of power supplies and may be supplemented with the use of a External Power Supply (EPS). |
Idle power is the actual power consumption of the device with no ports connected. Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated. PoE Power is the power supplied by the internal power supply, it is dependent on the type and quantity of power supplies and may be supplemented with the use of a External Power Supply (EPS). |
Idle power is the actual power consumption of the device with no ports connected. Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated. |
| Safety |
|
CSA 22.2 No. 60950 UL 60950 IEC 60950 EN 60950
|
CSA 22.2 No. 60950 UL 60950 IEC 60950 EN 60950
|
CSA 22.2 No. 60950 UL 60950 IEC 60950 EN 60950
|
| Notes |
|
When using mini-GBICs with this product, mini-GBICs with revision "B" or later (product number ends with the letter "B" or later, e.g., J4858B, J4859C) are required.
|
When using mini-GBICs with this product, mini-GBICs with revision "B" or later (product number ends with the letter "B" or later, e.g., J4858B, J4859C) are required.
|
When using mini-GBICs with this product, mini-GBICs with revision "B" or later (product number ends with the letter "B" or later, e.g., J4858B, J4859C) are required.
|